Hitachi HTS725050A9A364 Datasheet Page 103

  • Download
  • Add to my manuals
  • Print
  • Page
    / 176
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 102
7K500 OEM Specification
Page 103 of 176
14.12
14.1214.12
14.12 Initialize Device Parameters (91h)
Initialize Device Parameters (91h) Initialize Device Parameters (91h)
Initialize Device Parameters (91h)
Command Block Output Registers
Command Block Input Registers
Register 7
6
5
4
3
2
1
0
Register 7
6
5
4
3
2
1
0
Data -
-
-
-
-
-
-
-
Data -
-
-
-
-
-
-
-
Feature -
-
-
-
-
-
-
-
Error ...See Below...
Sector Count V
V
V
V
V
V
V
V
Sector Count -
-
-
-
-
-
-
-
LBA Low -
-
-
-
-
-
-
-
LBA Low -
-
-
-
-
-
-
-
LBA Mid -
-
-
-
-
-
-
-
LBA Mid -
-
-
-
-
-
-
-
LBA High -
-
-
-
-
-
-
-
LBA High -
-
-
-
-
-
-
-
Device -
-
-
-
H
H
H
H
Device -
-
-
-
-
-
-
-
Command 1
0
0
1
0
0
0
1
Status ...See Below...
Error Register
Status Register
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
CRC
UNC
0 IDN
0 ABT
T0N
AM
N
BSY
RDY
DF
DSC
DRQ
COR
IDX
ERR
0 0 0 0 0 V 0 0
0 0 0 - - 0 0 V
Table 67 Initialize Device Parameters Command (91h)
The Initialize Device Parameters command enables the host to set the number of sectors per track
and the number of heads minus 1, per cylinder. Words 54-58 in Identify Device Information reflects
these parameters.
The parameters remain in effect until the following events:
Another Initialize Device Parameters command is received.
The device is powered off.
Soft reset occurs and the Set Feature option of CCh is set
Output Parameters To The Device
Sector Count
The number of sectors per track. 0 does not mean there are 256 sectors per track, but there is no
sector per track.
H
The number of heads minus 1 per cylinder. The minimum is 0 and the maximum is 15.
Page view 102
1 2 ... 98 99 100 101 102 103 104 105 106 107 108 ... 175 176

Comments to this Manuals

No comments