7K500 OEM Specification
Page 54 of 176
HTS7250XXA9A3XX support both Logical CHS Addressing Mode and LBA Addressing Mode as the
sector addressing mode.
The host system may select either the currently selected CHS translation addressing or LBA
addressing on a command-by-command basis by using the L bit in the DEVICE register. So a host
system must set the L bit to 1 if the host uses LBA Addressing mode.
12.4.1
12.4.112.4.1
12.4.1
Logical CHS Addressing Mode
Logical CHS Addressing Mode Logical CHS Addressing Mode
Logical CHS Addressing Mode
The logical CHS addressing is made up of three fields: the cylinder number, the head number and
the sector number. Sectors are numbered from 1 to the maximum value allowed by the current CHS
translation mode but can not exceed 255(0FFh). Heads are numbered from 0 to the maximum value
allowed by the current CHS translation mode but can not exceed 15(0Fh). Cylinders are numbered
from 0 to the maximum value allowed by the current CHS translation mode but cannot exceed
65535(0FFFFh).
When the host selects a CHS translation mode using the INITIALIZE DEVICE PARAMETERS
command, the host requests the number of sectors per logical track and the number of heads per
logical cylinder. The device then computes the number of logical cylinders available in requested
mode.
The default CHS translation mode is described in the Identify Device Information. The current CHS
translation mode also is described in the Identify Device Information.
12.4.2
12.4.212.4.2
12.4.2
LBA Addressing Mode
LBA Addressing Mode LBA Addressing Mode
LBA Addressing Mode
Logical sectors on the device shall be linearly mapped with the first LBA addressed sector (sector 0)
being the same sector as the first logical CHS addressed sector ( cylinder 0, head 0, sector 1).
Irrespective of the logical CHS translation mode currently in effect, the LBA address of a given
logical sector does not change. The following is always true:
LBA = ( (cylinder * heads_per_cylinder + heads)
* sectors_per_track ) + sector - 1
where heads_per_cylinder and sectors_per_track are the current translation mode values.
On LBA addressing mode, the LBA value is set to the following register.
Device <--- LBA bits 27-24
LBA High <--- LBA bits 23-16
LBA Mid <--- LBA bits 15- 8
LBA Low <--- LBA bits 7- 0
12.5
12.512.5
12.5 Power Management Feature
Power Management Feature Power Management Feature
Power Management Feature
The power management feature set permits a host to modify the behavior in a manner which
reduces the power required to operate. The power management feature set provides a set of
commands and a timer that enables a device to implement low power consumption modes.
HTS7250XXA9A3XX implements the following set of functions.
1.
A Standby timer
2.
Idle command
3.
Idle Immediate command
4.
Sleep command
5.
Standby command
6.
Standby Immediate command
12.5.1
12.5.112.5.1
12.5.1
Power Mode
Power Mode Power Mode
Power Mode
Sleep Mode
The lowest power consumption when the device is powered on occurs in Sleep Mode.
When in sleep mode, the device requires a reset to be activated.
Standby Mode
The device interface is capable of accepting commands, but as the media may not
Page view 53