7K500 OEM Specification
Page 74 of 176
Code
Protocol
Command
(Hex)
7
6
5
4
3
2
1
0
3 Set Max Address F9 1
1
1
1
1
0
0
1
3 Set Max Address Ext 37 0
0
1
1
0
1
1
1
3 Set Max Freeze Lock F9 1
1
1
1
1
0
0
1
3 Set Max Lock F9 1
1
1
1
1
0
0
1
2 Set Max Set Password F9 1
1
1
1
1
0
0
1
2 Set Max Unlock F9 1
1
1
1
1
0
0
1
3 Set Multiple Mode C6 1
1
0
0
0
1
1
0
3 Sleep E6 1
1
1
0
0
1
1
0
3 Sleep* 99 1
0
0
1
1
0
0
1
3 S.M.A.R.T. Disable Operations B0 1
0
1
1
0
0
0
0
3 S.M.A.R.T. Enable/Disable Attribute Auto save B0 1
0
1
1
0
0
0
0
3 S.M.A.R.T. Enable/Disable Automatic Off-line B0 1
0
1
1
0
0
0
0
3 S.M.A.R.T. Enable Operations B0 1
0
1
1
0
0
0
0
3 S.M.A.R.T. Execute Off-line Immediate B0 1
0
1
1
0
0
0
0
1 S.M.A.R.T. Read Attribute Values B0 1
0
1
1
0
0
0
0
1 S.M.A.R.T. Read Attribute Thresholds B0 1
0
1
1
0
0
0
0
1 S.M.A.R.T. Read Log Sector B0 1
0
1
1
0
0
0
0
3 S.M.A.R.T. Return Status B0 1
0
1
1
0
0
0
0
3 S.M.A.R.T. Save Attribute Values B0 1
0
1
1
0
0
0
0
2 S.M.A.R.T. Write Log Sector B0 1
0
1
1
0
0
0
0
3 Standby E2 1
1
1
0
0
0
1
0
3 Standby* 96 1
0
0
1
0
1
1
0
3 Standby Immediate E0 1
1
1
0
0
0
0
0
3 Standby Immediate* 94 1
0
0
1
0
1
0
0
2 Write Buffer E8 1
1
1
0
1
0
0
0
4 Write DMA CA 1
1
0
0
1
0
1
0
4 Write DMA CB 1
1
0
0
1
0
1
1
4 Write DMA Ext 35 0
0
1
1
0
1
0
1
4 Write DMA FUA Ext 3D 0
0
1
1
1
1
0
1
5 Write FPDMA Queued 61 0
1
1
0
0
0
0
1
2 Write Log Ext 3F 0
0
1
1
1
1
1
1
2 Write Multiple C5 1
1
0
0
0
1
0
1
2 Write Multiple Ext 39 0
0
1
1
1
0
0
1
2 Write Multiple FUA Ext CE 1
1
0
0
1
1
1
0
2 Write Sector(s) 30 0
0
1
1
0
0
0
0
2 Write Sector(s) 31 0
0
1
1
0
0
0
1
2 Write Sector(s) Ext 34 0
0
1
1
0
1
0
0
3 Write Uncorrectable Ext 45 0
1
0
0
0
1
0
1
Protocol : 1 : PIO data IN command
2 : PIO data OUT command
3 : Non data command
4 : DMA command
5 : First-parity DMA command
+ : Vendor specific command
Table 41 Command Set - continued
Commands marked * are alternate command codes for previously defined commands.