Hitachi HTS725050A9A364 Datasheet Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 176
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
7K500 OEM Specification
Page 48 of 176
SRST (RST)
Software Reset. The device is held reset when RST=1. Setting RST=0 reenables the device.
The host must set RST=1 and wait for at least 5 microseconds before setting RST=0, to
ensure that the device recognizes the reset.
-IEN
Interrupt Enable. When IEN=0, and the device is selected, device interrupts to the host will
be enabled. When IEN=1, or the device is not selected, device interrupts to the host will be
disabled.
11.4
11.411.4
11.4 Device Register
Device Register Device Register
Device Register
Device Register
7 6 5 4 3 2 1 0
- L - 0 HS3 HS2 HS1 HS0
Table 26 Device Register
This register contains the device and head numbers.
Bit Definitions
L
Binary encoded address mode select. When L=0, addressing is by CHS mode. When L=1,
addressing is by LBA mode.
HS3,HS2,HS1,HS0
The HS3 through HS0 contain bits 24-
27 of the LBA. At command completion, these bits are
updated to reflect the current LBA bits 24-27.
11.5
11.511.5
11.5 Error Regis
Error RegisError Regis
Error Register
ter ter
ter
Error Register
7 6 5 4 3 2 1 0
CRC UNC 0 IDNF 0 ABRT TK0NF AMNF
Table 27 Error Register
This register contains status from the last command executed by the device, or a diagnostic code.
At the completion of any command except Execute Device Diagnostic, the contents of this register
are valid always even if ERR=0 in the Status Register.
Following a power on, a reset, or completion of an Execute Device Diagnostic command, this register
contains a diagnostic code. See “Table 31 Diagnostic Codes” on Page 52 for the definition.
Bit Definitions
ICRCE (CRC)
Interface CRC Error. CRC=1 indicates a CRC error has occurred on the data bus during a
Ultra-DMA transfer.
UNC
Uncorrectable Data Error. UNC=1 indicates an uncorrectable data error has been
encountered.
IDNF (IDN)
ID Not Found. IDN=1 indicates the requested sector’s ID field could not be found.
ABRT (ABT)
Aborted Command. ABT=1 indicates the requested command has been aborted due to a
device status error or an invalid parameter in an output register.
TK0NF (T0N)
Track 0 Not Found. T0N=1 indicates track 0 was not found during a Recalibrate command.
AMNF (AMN)
Address Mark Not Found. AMN=1 indicates the data address mark has not been found after
finding the correct ID field for the requested sector.
This bit is obsolete.
11.6
11.611.6
11.6 Features Register
Features Register Features Register
Features Register
This register is command specific. This is used with the Set Features command, S.M.A.R.T. Function
Set command and Format Unit command.