9.1.1 Register initialization
After power on, hard reset, or software reset, the register values are initialized as shown in the figure
below.
50hAlternate Status
50hStatus
A0hDevice/Head
00hCylinder High
00hCylinder Low
01hSector Number
01hSector Count
Diagnostic CodeError
Default ValueRegister
Figure 76. Default Register Values
The meaning of the Error Register diagnostic codes resulting from power on, hard reset, or the Execute
Device Diagnostic command is shown in the figure below.
Device 1 failed8xh
Controller microprocessor error05h
ECC circuitry error04h
Sector buffer error03h
Formatter device error02h
No error detected01h
DescriptionCode
Figure 77. Diagnostic Codes