Hitachi L100 User Manual Page 132

  • Download
  • Add to my manuals
  • Print
  • Page
    / 163
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 131
L100 Inverter
Troubleshooting
and Maintenance
6–7
NOTE: If an EEPROM error (E08) occurs, be sure to confirm the parameter data values
are still correct. If the power is turned off while the [RS] (Reset) intelligent input
terminal is On, an EEPROM error will occur when power is restored.
E35
PTC error When intelligent terminal 5 is configured for PTC
(protective thermistor) function and the inverter has
sensed the resistance is too high (wire is broken or
temperature is too high), the inverter trips and turns
off the output.
Error
Code
Name Cause(s)