Hitachi Webcam kp-f500pcl/scl User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 41
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
14
1. Send data (Setting command. Note: 1 to 7 and SUM need to be transformed into ASCII code)
1 2 3 4 5 6 7
Item STX
STATUS ID NO.
AREA
ADDRESS
RELATIVE
NO.
DATA
ETX SUM
OFF 02 01 FF 01 04 00 00 00 03 28
FIXED 02 01 FF 01 04 01 00 00 03 27
1TRIG 02 01 FF 01 04 02 00 00 03 26
MODE
VD CONT 02 01 FF 01 04 04 00 00 03 24
POSITIVE 02 01 FF 01 0F 00 00 00 03 16
POLARITY
NEGATIVE 02 01 FF 01 0F 01 00 00 03 15
CL-CC1 02 01 FF 01 05 00 00 00 03 26
TRIGGER
SOURCE
12pin 02 01 FF 01 05 01 00 00 03 25
OFF 02 01 FF 01 06 00 00 00 03 26
FLASH OUT 02 01 FF 01 06 01 00 00 03 25
OUTPUT SIGNAL
VD 02 01 FF 01 06 02 00 00 03 24
OFF 02 01 FF 01 08 00 00 00 03 24
1/16 02 01 FF 01 08 01 00 00 03 23
1/60 02 01 FF 01 08 02 00 00 03 22
1/100 02 01 FF 01 08 03 00 00 03 21
1/250 02 01 FF 01 08 04 00 00 03 20
1/1000 02 01 FF 01 08 05 00 00 03 1F
1/2000 02 01 FF 01 08 06 00 00 03 1E
1/10000 02 01 FF 01 08 07 00 00 03 1D
1/50000 02 01 FF 01 08 08 00 00 03 1C
PRESET
VARIABLE (*2) 02 01 FF 01 08 FF 00 00 03 F8
MIN (1/100000(s)) 02 01 FF 01 11 00 (*3) 00 (*3) 00 03 2A
SHUTTER
SPEED
(*1)
VARIABLE VALUE
(2Byte) (*2)
MAX (10(s)) 02 01 FF 01 11 06 (*3) 00 (*3) 00 03 1E
BASE 02 01 FF 01 12 00 00 00 03 29
CONFIGURATION
MEDIUM 02 01 FF 01 12 01 00 00 03 28
8bit 02 01 FF 01 14 00 00 00 03 27
10bit 02 01 FF 01 14 01 00 00 03 26
DATA BIT
12bit 02 01 FF 01 14 02 00 00 03 25
VD 02 01 FF 01 15 00 00 00 03 26
VD/FVAL
FVAL 02 01 FF 01 15 01 00 00 03 25
HD 02 01 FF 01 16 00 00 00 03 25
LVAL 02 01 FF 01 16 01 00 00 03 24
HD/LVAL
LVAL2 02 01 FF 01 16 02 00 00 03 23
MIN (0) 02 01 FF 01 0C 00 (*4) 00 (*4) 00 03 19
GAIN (2Byte)
MAX (503/336) (*4) 02 01 FF 01 0C 01 (*4) F7/50(*4) 00 03 FB/13
MIN (0) 02 01 FF 01 17 00 (*5) 00 00 03 24
BLACK LEVEL
MAX (63) 02 01 FF 01 17 3F (*5) 00 00 03 0B
OFF 02 01 FF 01 13 00 00 00 03 28 VERTICAL 2 PIXEL
ADDITION (*6)
ON 02 01 FF 01 13 01 00 00 03 27
OFF 02 01 FF 01 1E 00 00 00 03 16
MODE
ON (*6) 02 01 FF 01 1E 01 00 00 03 15
MIN (1) 02 01 FF 01 1F 00 01 00 03 14 START
(2BYTE) (*7)
MAX (2058) 02 01 FF 01 1F 08 (*8) 0A (*8) 00 03 FC
MIN (1) 02 01 FF 01 20 00 01 00 03 29
PARTIAL
SCAN
WIDTH
(2BYTE) (*7)
MAX (2058) 02 01 FF 01 20 08 (*8) 0A (*8) 00 03 11
(*1) SHUTTER SPEED settings are effective only in the condition TRIGGER MODE is OFF or FIXED SHUTTER.
(*2) VARIABLE VALUE can be set only when VARIABLE is selected.
(*3) VARIABLE VALUE: selectable in the range from 0000 to 0600
16
(See page 5 to 6 about setting shutter speed).
(*4) GAIN: selectable in the range from 0000
16
to 01F7
16
: KP-F500PCL/SCL.
from 0000
16
to 0150
16
: KP-FR500PCL/SCL.
(*5) BLACK LEVEL: selectable in the range from 00
16
to 3F
16
.
(*6) VERTICAL 2 PIXEL ADDITION is only for KP-F500PCL/SCL.
(*7) PARTIAL SCAN START/WIDTH can be set only when PARTIAL SCAN MODE is ON.
(*8) PARTIAL SCAN START/WIDTH: selectable in the range from 0001
16
to 080A
16
and the sum total of START and WIDTH is 080A
16
or less.
Command list
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 40 41

Comments to this Manuals