Hitachi CP-X440 User Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
40
Maintenance
When the indicators or a message prompts you to clean the air filter, clean the air filter
as soon as possible. Please check and clean the air lter periodically, even if there is no
message. If the air lter becomes clogged by dust or the like, internal temperatures rise
and the power may be automatically turned off for malfunction prevention.
1.
Turn the projector off, and unplug the power cord.
Allow the projector to cool for at least 45 minutes. And
prepare a vacuum cleaner.
2.
After making sure that the projector is cool adequately,
slowly turn the projector so that the lens-side is facing
up. Please be careful for the projector not to fall. While
the projector is placed lens-side up, hold the projector.
3.
Unhooking the fi lter cover’s claws, and pull the fi lter
cover in the direction of the arrow to remove it.
4.
Hold the air fi lter’s knob, and pull the air fi lter off.
5.
Apply a vacuum cleaner to the vent of the projector for the
air fi lter. And then slowly turn the projector bottom up.
6.
Apply a vacuum cleaner to the air lter and the fi lter cover.
Please replace the air fi lter when it is damaged or too soiled.
Please replace the air fi lter when it is damaged or too soiled.
To prepare a new air fi lter, contact your dealer and tell the air
lter type number =
NJ20642.
An air fi lter of specifi ed type will come even with a replacement lamp for this projector.
7.
Position the cleaned air fi lter or a new air fi lter into place, and push the
"PUSH" mark with claws to fi x the air fi lter.
8.
Replace the fi lter cover and snap it back into place.
9.
Slowly turn the projector so that the top is facing up.
10.
Turn the projector on, and reset the fi lter time using the FILTER TIME
function of the OPTION menu
(
36
)
.
NOTE
Incorrectly resetting of the fi lter timer (resetting without replacement,
or neglect of resetting after replacement) will result in incorrect message functions.
WARNING
Before caring, make sure the power switch is off and the
power cable is not plugged in,
then allow
the projector to cool suffi ciently
.
The
care in a high temperature state of the projector could cause a burn and/or
malfunction to the projector
.
Use only the air fi lter of the specifi ed type. Do not use the projector with the
air fi lter and the fi lter cover removed.
Avoid wetting the projector or inserting liquids in the projector. It could result
in a fi re, an electric shock, and/or malfunction to the projector
.
CAUTION
►Please replace the air fi lter when it is damaged or too soiled,
and also when you replace the lamp.
Air fi lter
Filter cover’s claws
Filter cover
Air fi lter
Air fi lter’s knob
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 63 64

Comments to this Manuals

No comments